EN 50160:2010 – Voltage characteristics of electricity supplied by public electricity networks

EN 50160:2010 - Voltage characteristics of electricity supplied by public electricity networks

4.2.2 Supply voltage variations 4.2.2.1 Requirements Under normal operating conditions excluding the periods with interruptions, supply voltage variations should not exceed ± 10 % of the nominal voltage U n . In cases of electricity supplies in networks not interconnected with transmission systems or for special remote network users, voltage variations should not exceed + 10 % / – 15 […]

Continue reading »

EN 50180:2010 – Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers

EN 50180:2010 - Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers

1 Scope This European Standard is applicable to ceramic and resin insulated bushings having highest voltages above 1 kV up to 52 kV, rated currents from 250 A up to 3 150 A and frequencies from 15 Hz up to 60 Hz for insulating liquid filled transformers. This standard establishes essential dimensions, to ensure interchangeability of bushings and to ensure […]

Continue reading »

EN 50191:2010 – Erection and operation of electrical test equipment

EN 50191:2010 - Erection and operation of electrical test equipment

4.1.1.1 Test assembly The test assembly shall be so arranged and designed that the protection against direct contact is secured by insulation of live parts, covers, enclosures, obstacles or safe distances. A safe distance is ensured, when the person carrying out the tests cannot reach the prohibition zone with parts of his/her body or tools. Safety can also be satisfied […]

Continue reading »

EN 50364:2010 – Limitation of human exposure to electromagnetic fields from devices operating in the frequency range 0 Hz to 300 GHz, used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications

EN 50364:2010 - Limitation of human exposure to electromagnetic fields from devices operating in the frequency range 0 Hz to 300 GHz, used in Electronic Article Surveillance (EAS), Radio Frequency Identification (RFID) and similar applications

1 Scope This product standard applies to devices operating within the frequency range 0 Hz to 300 GHz, used in electronic article surveillance (EAS), radio frequency identification (RFID) and similar applications. This product standard may be used for demonstration of compliance to the requirements of the RTTE Directive 1999/5/EC, with regard to the limitation of human exposure to electromagnetic fields […]

Continue reading »

EN 50383:2010 – Basic standard for the calculation and measurement of electromagnetic field strength and SAR related to human exposure from radio base stations and fixed terminal stations for wireless telecommunication systems (110 MHz – 40 GHz)

EN 50383:2010 - Basic standard for the calculation and measurement of electromagnetic field strength and SAR related to human exposure from radio base stations and fixed terminal stations for wireless telecommunication systems (110 MHz - 40 GHz)

1 Scope This basic standard applies to radio base stations and fixed terminal stations for wireless telecommunication systems as defined in Clause 4, operating in the frequency range 110 MHz to 40 GHz. The objective of the standard is to specify, for such equipment, the method for assessment of compliance distances according to the basic restrictions (directly or indirectly via […]

Continue reading »

EN 50543:2011 – Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air – Requirements and test methods

EN 50543:2011 - Electronic portable and transportable apparatus designed to detect and measure carbon dioxide and/or carbon monoxide in indoor ambient air - Requirements and test methods

1 Scope This European Standard specifies requirements for the construction, testing and performance of electronic portable and transportable apparatus for the detection and measurement of carbon dioxide (CO 2 ) and/or carbon monoxide (CO) in indoor ambient air, which includes air entering mechanical ventilation systems in domestic residential, commercial and industrial premises and public buildings. This European Standard includes indoor […]

Continue reading »

EN 50556:2011 – Road traffic signal systems

EN 50556:2011 - Road traffic signal systems

5 Safety 5.1 Electrical safety 5.1.1 General 5.1.1.1 Introduction The Road Traffic Signal System shall conform to HD 384.4 series. This subclause deals with the additional requirements for Road Traffic Signal Systems. 5.1.1.2 Criteria − Leakage current 5.1.1.2.1 Road Traffic Signal Systems Class T1: For Road Traffic Signal Systems, leakage current protection facilities conforming to HD 384.4.41 shall be fitted. […]

Continue reading »

EN 50563:2011 – External a.c. – d.c. and a.c. – a.c. power supplies – Determination of no-load power and average efficiency of active modes

EN 50563:2011 - External a.c. - d.c. and a.c. - a.c. power supplies – Determination of no-load power and average efficiency of active modes

4 Information and instructions for use 4.1 Information to be provided on or with the ex ternal power supply The i nf orm ation below shall either be marked on eac h externa l power supply or contained in documentatio n provided with eac h external powe r supply: • rated output voltage, in V, • symbo l ind ica […]

Continue reading »

EN 61210:2010 – Connecting devices – Flat quick-connect terminations for electrical copper conductors – Safety requirements

EN 61210:2010 - Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements

1 Scope This International Standard applies to non-insulated flat quick-connect terminations consisting of a male tab of size 2,8 mm, 4,8 mm, 6,3 mm or 9,5 mm with hole or dimple detents and a mating female connector for use as either an incorporated or an integrated part of an equipment or of a component, or as a separate entity. This […]

Continue reading »

EN 61373:2010 – Railway applications – Rolling stock equipment – Shock and vibration tests

EN 61373:2010 - Railway applications - Rolling stock equipment - Shock and vibration tests

1 Scope This International Standard specifies the requirements for testing items of equipment intended for use on railway vehicles which are subsequently subjected to vibrations and shock owing to the nature of railway operational environment. To gain assurance that the quality of the equipment is acceptable, it has to withstand tests of reasonable duration that simulate the service conditions seen […]

Continue reading »